Changes

Jump to navigation Jump to search
no edit summary
Line 23: Line 23:  
The following normative documents contain provisions that, through reference in this text, constitute provisions of this National Standard of Canada. The referenced documents may be obtained from the sources noted below.<br>
 
The following normative documents contain provisions that, through reference in this text, constitute provisions of this National Standard of Canada. The referenced documents may be obtained from the sources noted below.<br>
 
NOTE The addresses provided below were valid at the date of publication of this standard.<br>
 
NOTE The addresses provided below were valid at the date of publication of this standard.<br>
 +
An undated reference is to the latest edition or revision of the reference or document in question, unless otherwise specified by the authority applying this standard. A dated reference is to the specified revision or edition of the reference or document in question. <br>
 +
See Annex B for regulations that apply to heating fuel oil.<br>
 +
The testing and evaluation of a product against this standard may require the use of materials and/or equipment that could be hazardous. This document does not purport to address all the safety aspects associated with its use. Anyone using this standard has the responsibility to consult the appropriate authorities and to establish appropriate health and safety practices in conjunction with any applicable regulatory requirements prior to its use.<br>
   −
An undated reference is to the latest edition or revision of the reference or document in question, unless otherwise specified by the authority applying this standard. A dated reference is to the specified revision or edition of the reference or document in question.
   
<h2>Canadian General Standards Board (CGSB)</h2>
 
<h2>Canadian General Standards Board (CGSB)</h2>
 
CAN/CGSB-3.0 – ''Methods of testing petroleum and associated products'': No. 28.8 – ''Visual haze rating of liquid fuels''<br>
 
CAN/CGSB-3.0 – ''Methods of testing petroleum and associated products'': No. 28.8 – ''Visual haze rating of liquid fuels''<br>
 
CAN/CGSB-3.524 — ''Biodiesel (B100) for blending in middle distillate fuel''.<br>
 
CAN/CGSB-3.524 — ''Biodiesel (B100) for blending in middle distillate fuel''.<br>
'''2.1.1 Source'''
+
'''2.1.1 Source''' <br>
 
The above may be obtained from the Canadian General Standards Board, Sales Centre, Gatineau, Canada K1A 1G6. Telephone 819-956-0425 or 1-800-665-2472. Fax 819-956-5740. E-mail ncr.cgsb-ongc@tpsgc-pwgsc.gc.ca. Web site www.tpsgc-pwgsc.gc.ca/ongc-cgsb/index-eng.html.<br>
 
The above may be obtained from the Canadian General Standards Board, Sales Centre, Gatineau, Canada K1A 1G6. Telephone 819-956-0425 or 1-800-665-2472. Fax 819-956-5740. E-mail ncr.cgsb-ongc@tpsgc-pwgsc.gc.ca. Web site www.tpsgc-pwgsc.gc.ca/ongc-cgsb/index-eng.html.<br>
   Line 37: Line 39:     
Web site: http://www.canadianfuels.ca/Fuels-and-Transportation/Conventional-Transportation-Fuels/.
 
Web site: http://www.canadianfuels.ca/Fuels-and-Transportation/Conventional-Transportation-Fuels/.
  −
See Annex B for regulations that apply to heating fuel oil.<br>
  −
  −
The testing and evaluation of a product against this standard may require the use of materials and/or equipment that could be hazardous. This document does not purport to address all the safety aspects associated with its use. Anyone using this standard has the responsibility to consult the appropriate authorities and to establish appropriate health and safety practices in conjunction with any applicable regulatory requirements prior to its use.<br>
      
<h2> ASTM International </h2>
 
<h2> ASTM International </h2>
Line 70: Line 68:  
<h1> Classification </h1>
 
<h1> Classification </h1>
 
'''4.1 '''
 
'''4.1 '''
Heating fuel oils shall be supplied in the following types, as specified (see 8.1):
+
Heating fuel oils shall be supplied in the following types, as specified (see 8.1):<br>
4.1.1 Types
+
 
 +
4.1.1 Types<br>
 
Type 0<br>
 
Type 0<br>
 
Type 1<br>
 
Type 1<br>
Line 92: Line 91:  
'''6.1.3''' If an alternate test method referenced in this standard provides a bias correction to the referee method, adherence to the specified limiting value shall be based on the bias-corrected result.<br>
 
'''6.1.3''' If an alternate test method referenced in this standard provides a bias correction to the referee method, adherence to the specified limiting value shall be based on the bias-corrected result.<br>
 
'''6.1.4''' Where test values differ between two parties, a resolution shall be in accordance with ASTM D3244 in order to determine conformance with the specified limiting values, with the criticality of the limits set at P = 0.5.<br>
 
'''6.1.4''' Where test values differ between two parties, a resolution shall be in accordance with ASTM D3244 in order to determine conformance with the specified limiting values, with the criticality of the limits set at P = 0.5.<br>
'''6.1.5'''Zeroes trailing the last nonzero digit for numbers represented with a decimal point are significant digits, in accordance with ASTM E29.
+
'''6.1.5''' Zeroes trailing the last nonzero digit for numbers represented with a decimal point are significant digits, in accordance with ASTM E29.
 
<h2> Test methods </h2>
 
<h2> Test methods </h2>
 
'''6.2.1''' Test methods other than those referenced in this standard may be used only if they have been validated in accordance with ASTM D3764 or D6708.<br>
 
'''6.2.1''' Test methods other than those referenced in this standard may be used only if they have been validated in accordance with ASTM D3764 or D6708.<br>
Line 100: Line 99:  
'''6.2.5''' If parties in a dispute cannot agree on an analytical method to resolve the dispute, the referee method listed in the standard shall be used.<br>
 
'''6.2.5''' If parties in a dispute cannot agree on an analytical method to resolve the dispute, the referee method listed in the standard shall be used.<br>
   −
 
+
{| class="wikitable"
 +
|-
 +
! Specified limiting values
 +
|-
 +
! # !! Property !! Limit !! Type 0 !! Type 1 !! Type 2 !! Type 4 !! Type 5 !! Type 6 !! Test Method (ASTM)
 +
|-
 +
| '''6.3''' || Flash point, °C (see 6.19) || Min. || 40.0 || 40.0 || 40.0 || 54.0 || 54.0 || 60.0 || D93, D3828, D7049
 +
|-
 +
| '''6.4''' || Kinematic viscosity, at 40°C, mm<sup>2</sup>/s (cSt)(see 6.25) || Min. || 1.20 || 1.30 || 1.70 || 5.5 || ― || ― ||D445, D7042 or D7945
 +
|-
 +
|  || || Max. || 2.00 || 2.50 || 3.60 || 24.0 || ― || ―
 +
|-
 +
| '''6.6''' || Distillation (see 6.20) ||  ||  ||  ||  ||  ||  ||  || D86, D2887, or D7345
 +
|-
 +
| 6.6 a || 10% recovered, °C || Max. || ― || 215 || ― || ― || ― || ― ||
 +
|-
 +
| 6.6 b || 90% recovered, °C || Max. || ― || 300. || 360. ||  ―  ||  ―  ||  ― ||
 +
|-
 +
| 6.6 c || end point, °C  || Max. || 300. || ― || ― || ― || ― || ― || 
 +
|-
 +
| Example || Example || Example || Example || Example || Example || Example || Example || Example
 +
|-
 +
| Example || Example || Example || Example || Example || Example || Example || Example || Example
 +
|-
 +
| Example || Example || Example || Example || Example || Example || Example || Example || Example
 +
|-
 +
| Example || Example || Example || Example || Example || Example || Example || Example || Example
 +
|-
 +
| Example || Example || Example || Example || Example || Example || Example || Example || Example
 +
|}
     

Navigation menu

GCwiki