Line 431: |
Line 431: |
| (2) | | (2) |
| | | |
− | Where is the corrected meter reading of the working standard under the identical conditions of measurement as those established for the measurement of air kerma rate, ''K<sub>a</sub>'', given by Eq. 1. The accuracy of dosimetry for radiation therapy and radiation safety is vital. Accuracy of radiation dosimetry depends on the quality of calibration of the device used to quantify the radiation dose. Calibration of such an equipment can be performed in two types of laboratories: primary standard lab also which mostly are commonly called national meteorological institute in the country or at a secondary standard laboratory. A primary laboratory maintains the primary standard for measurement of ionizing radiation in SI units which is compared and calibrated with the standard maintained in BIPM whereas the secondary lab maintains the standard which is used to calibrate dosimeters and survey meters which is traceable one of the NIMs. In Canada, the NRC MSS maintains primary standards for ionizing radiation. CNSC lab has been maintaining the reference standards for ionizing radiation (air kerma and ambient dose equivalent for radiation protection) as an accredited lab since November 2016. CNSC laboratory has been recently recognized by IAEA/WHO as a secondary standard lab, which maintains the secondary standard for air kerma in SI units in Cs-137 field for radiation protection dosimetry and disseminates it through calibration of standards to use within the lab and for the standardization of Cs-137 field to calibrate gamma survey instruments and electronic personal dosimeters. The CNSC Laboratory, as a full member of the network, is committed to adhering to the network's charter and serving users of ionizing radiation across the country under its mandate in collaboration with National Research Council of Canada (Primary Standard Laboratory for ionizing radiation in Canada) and internationally through the IAEA SSDL program. | + | Where is the corrected meter reading of the working standard under the identical conditions of measurement as those established for the measurement of air kerma rate, ''K<sub>a</sub>'', given by Eq. 1. |
| + | |
| + | The accuracy of dosimetry for radiation therapy and radiation safety is vital. Accuracy of radiation dosimetry depends on the quality of calibration of the device used to quantify the radiation dose. Calibration of such an equipment can be performed in two types of laboratories: primary standard lab also which mostly are commonly called national meteorological institute in the country or at a secondary standard laboratory. A primary laboratory maintains the primary standard for measurement of ionizing radiation in SI units which is compared and calibrated with the standard maintained in BIPM whereas the secondary lab maintains the standard which is used to calibrate dosimeters and survey meters which is traceable one of the NIMs. In Canada, the NRC MSS maintains primary standards for ionizing radiation. CNSC lab has been maintaining the reference standards for ionizing radiation (air kerma and ambient dose equivalent for radiation protection) as an accredited lab since November 2016. CNSC laboratory has been recently recognized by IAEA/WHO as a secondary standard lab, which maintains the secondary standard for air kerma in SI units in Cs-137 field for radiation protection dosimetry and disseminates it through calibration of standards to use within the lab and for the standardization of Cs-137 field to calibrate gamma survey instruments and electronic personal dosimeters. The CNSC Laboratory, as a full member of the network, is committed to adhering to the network's charter and serving users of ionizing radiation across the country under its mandate in collaboration with National Research Council of Canada (Primary Standard Laboratory for ionizing radiation in Canada) and internationally through the IAEA SSDL program. |
| | | |
| The CNSC laboratory is equipped with a radiation protection level gamma irradiator that provides a range of air kerma and dose equivalent rates in Cs-137 gamma radiation fields, as well as a variety of low activity traceable wide area radioactive sources, calibrated neutron Am-Be sources, and a neutron irradiator. As an SSDL, the CNSC Laboratory maintains a full set of reference ion chambers and electrometers that are traceable to National Research Council of Canada (NRC) in SI units for air kerma and provides calibration services for portable radiation safety equipment and reference standards to internal CNSC clients, including CNSC inspectors, other federal and provincial government departments under MOUs. | | The CNSC laboratory is equipped with a radiation protection level gamma irradiator that provides a range of air kerma and dose equivalent rates in Cs-137 gamma radiation fields, as well as a variety of low activity traceable wide area radioactive sources, calibrated neutron Am-Be sources, and a neutron irradiator. As an SSDL, the CNSC Laboratory maintains a full set of reference ion chambers and electrometers that are traceable to National Research Council of Canada (NRC) in SI units for air kerma and provides calibration services for portable radiation safety equipment and reference standards to internal CNSC clients, including CNSC inspectors, other federal and provincial government departments under MOUs. |
Line 442: |
Line 444: |
| | | |
| {| class="wikitable" | | {| class="wikitable" |
− | | CNSC Priority | + | |CNSC Priority |
− | | Description on CNSC Laboratory alignment with the priority | + | |Description on CNSC Laboratory alignment with the priority |
| |- | | |- |
− | | Modern | + | |Modern |
− | | Adopting latest standards ISO/IEC 17025 for Laboratory management for calibration services and recognition with IAEA as a secondary standard lab to promote accuracy, traceability of ionizing radiation in SI units | + | |Adopting latest standards ISO/IEC 17025 for Laboratory management for calibration services and recognition with IAEA as a secondary standard lab to promote accuracy, traceability of ionizing radiation in SI units |
| |- | | |- |
− | | Trusted | + | |Trusted |
− | | Recognition by national institutes such as standards council of Canada and NRC MSS as an ISO/IEC 17025 accredited lab and recently by IAEA as a full member of the network | + | |Recognition by national institutes such as standards council of Canada and NRC MSS as an ISO/IEC 17025 accredited lab and recently by IAEA as a full member of the network |
| |- | | |- |
− | | Global | + | |Global |
− | | Participate in global network of SSDLs to aimed to improve the accuracy of radiation dosimetry and to support network members globally through IAEA | + | |Participate in global network of SSDLs to aimed to improve the accuracy of radiation dosimetry and to support network members globally through IAEA |
| |- | | |- |
− | | Agile | + | |Agile |
− | | Continue to evolve and grow to meet demands of current and future needs. There is increasing trend among calibration laboratories to get accredited to universally accepted ISO 17025 standard | + | |Continue to evolve and grow to meet demands of current and future needs. There is increasing trend among calibration laboratories to get accredited to universally accepted ISO 17025 standard |
| |} | | |} |
| | | |