Fuel oils meeting the requirements of this standard are not intended for use in wick-type kerosene burning space heaters. When in doubt, consult the equipment operating instructions or the manufacturer of the appliance.
 
Fuel oils meeting the requirements of this standard are not intended for use in wick-type kerosene burning space heaters. When in doubt, consult the equipment operating instructions or the manufacturer of the appliance.
   −
'''9.2 Pour point'''
+
<h5>9.2 Pour point</h5>
 +
 
 
The pour point of the biodiesel fuel blend should be suitable as required for the conditions of storage and use or as agreed by contract. The addition of biodiesel can degrade the low temperature properties of the heating fuel oil. The effectiveness of some fuel additives can be affected when biodiesel is blended into the fuel.
 
The pour point of the biodiesel fuel blend should be suitable as required for the conditions of storage and use or as agreed by contract. The addition of biodiesel can degrade the low temperature properties of the heating fuel oil. The effectiveness of some fuel additives can be affected when biodiesel is blended into the fuel.
   −
'''9.3 Storage stability'''
+
<h5>9.3 Storage stability</h5>
Furnace burner manufacturers have expressed concerns with the stability of blends of biodiesel and middle distillate fuel. Poor oxidative stability of biodiesel blends can result in sediment formation and lacquering of furnace burner injection equipment. The inclusion of biodiesel in Type 2 heating fuel oil can degrade the storage stability of the finished fuel blend and long term storage (greater than 6 months) is not recommended. The impact of specific storage conditions has not been completely determined. The oxidation stability requirement of the B100 component is specified in CAN/CGSB-3.524.  
+
Furnace burner manufacturers have expressed concerns with the stability of blends of biodiesel and middle distillate fuel. Poor oxidative stability of biodiesel blends can result in sediment formation and lacquering of furnace burner injection equipment. The inclusion of biodiesel in Type 2 heating fuel oil can degrade the storage stability of the finished fuel blend and long term storage (greater than 6 months) is not recommended. The impact of specific storage conditions has not been completely determined. The oxidation stability requirement of the B100 component is specified in [http://www.publications.gc.ca/site/eng/9.838093/publication.html CAN/CGSB-3.524].  
    
'''9.4 Water and copper'''
 
'''9.4 Water and copper'''