|D97
 
|D97
 
|-
 
|-
| '''6.16''' || Cloud point, °C (see 6.24 and 8.1) || Max. || -48 || Report || Report || ―  || ―  || ―  || D2500 and D5773<ref name="a">The referee method to be used in the event of a dispute.</ref>  
+
| <h5>'''6.16'''</h5> || Cloud point, °C (see 6.24 and 8.1) || Max. || -48 || Report || Report || ―  || ―  || ―  || D2500 and D5773<ref name="a">The referee method to be used in the event of a dispute.</ref>  
 
|-
 
|-
| '''6.17''' Min. || Biodiesel, % by volume see 6.25 and Annex C) || Min. || ―  || ―  || ―  || ―  || ―  || ―  || D7371<ref name="a">The referee method to be used in the event of a dispute.</ref>,  or D7806
+
| <h5>'''6.17'''</h5> <abbr title="Minimum"> Min. || Biodiesel, % by volume see 6.25 and Annex C) || Min. || ―  || ―  || ―  || ―  || ―  || ―  || D7371<ref name="a">The referee method to be used in the event of a dispute.</ref>,  or D7806
 
|-
 
|-
| '''6.17''' Max. || Biodiesel, % by volume see 6.25 and Annex C)  || Max. || 0 || 0 || 5 || ―  || ―  || ―  || D7371<ref name="a">The referee method to be used in the event of a dispute.</ref>,  or D7806
+
| <h5>'''6.17'''</h5> <abbr title="Maximum"> Max. || Biodiesel, % by volume see 6.25 and Annex C)  || Max. || 0 || 0 || 5 || ―  || ―  || ―  || D7371<ref name="a">The referee method to be used in the event of a dispute.</ref>,  or D7806
 
|-
 
|-
| '''6.18''' || Lubricity, micrometers, µm (see 9.13)|| Max. || 520. || 520. || 520. || ― || ― || ― || D6079<ref name="a">The referee method to be used in the event of a dispute.</ref>,  or D7688
+
| <h5>'''6.18'''</h5> || Lubricity, micrometers, µm (see 9.13)|| Max. || 520. || 520. || 520. || ― || ― || ― || D6079<ref name="a">The referee method to be used in the event of a dispute.</ref>,  or D7688
 
|}<references />
 
|}<references />
   −
'''6.19'''   '''Flash point'''  The test values shall be reported to the nearest 0.5°C in accordance with ASTM D93, D3828 or D7094 (see 6.3 and table footnote b).
+
<h5>'''6.19'''</h5>  '''Flash point'''  The test values shall be reported to the nearest 0.5°C in accordance with ASTM D93, D3828 or D7094 (see 6.3 and table footnote b).
   −
'''6.20'''   '''Distillation''' When testing in accordance with ASTM D2887, use the method in the appendix to convert the results to estimates of ASTM D86. In the event of a dispute, the automated method of ASTM D86 shall be the referee test method.
+
<h5>'''6.20'''</h5>  '''Distillation''' When testing in accordance with ASTM D2887, use the method in the appendix to convert the results to estimates of ASTM D86. In the event of a dispute, the automated method of ASTM D86 shall be the referee test method.
   −
'''6.21'''   '''Water and sediment''' The test in ASTM D1796 shall be modified by substituting the centrifuge tube specified in ASTM D2273 for that in ASTM D1796. For Types 4, 5 and 6, ASTM D95 determines water by distillation and ASTM D473 determines sediment by extraction.
+
<h5>'''6.21'''</h5>  '''Water and sediment''' The test in ASTM D1796 shall be modified by substituting the centrifuge tube specified in ASTM D2273 for that in ASTM D1796. For Types 4, 5 and 6, ASTM D95 determines water by distillation and ASTM D473 determines sediment by extraction.
   −
'''6.22'''   '''Sulphur''' Sulphur content is established by government regulations in effect where the fuel oil is to be used, or by contractual agreement.
+
<h5>'''6.22'''</h5>  '''Sulphur''' Sulphur content is established by government regulations in effect where the fuel oil is to be used, or by contractual agreement.
   −
'''6.23'''   '''Pour point''' Pour point, except for Type 0, may be specified as required for the conditions of storage and use or as agreed by contract. Pour-depressed and flow-improved fuel oil that is designed to provide satisfactory performance under the conditions of storage and use may also be used.
+
<h5>'''6.23'''</h5>  '''Pour point''' Pour point, except for Type 0, may be specified as required for the conditions of storage and use or as agreed by contract. Pour-depressed and flow-improved fuel oil that is designed to provide satisfactory performance under the conditions of storage and use may also be used.
   −
'''6.24'''   '''Cloud point''' Cloud point for Types 1 and 2 may be specified as required by the conditions of storage and use or as agreed by contract.
+
<h5>'''6.24'''</h5>   '''Cloud point''' Cloud point for Types 1 and 2 may be specified as required by the conditions of storage and use or as agreed by contract.
   −
'''6.25   Biodiesel''' The biodiesel component shall comply with CAN/CGSB-3.524. Metered or measured volumes of added biodiesel shall be the primary measurement of biodiesel concentration. If an analytical test method has to be used for biodiesel concentration then use ASTM D7371 or D7806.
+
<h5>'''6.25'''</h5>  '''Biodiesel''' The biodiesel component shall comply with CAN/CGSB-3.524. Metered or measured volumes of added biodiesel shall be the primary measurement of biodiesel concentration. If an analytical test method has to be used for biodiesel concentration then use ASTM D7371 or D7806.
    
== '''7. Detailed requirements''' ==
 
== '''7. Detailed requirements''' ==
'''7.1     Sampling'''
+
<h5>'''7.1'''</h5>'''7.1     Sampling'''
    
'''7.1.1'''     Sampling equipment and procedures shall be designed and used to obtain representative samples of a product. Sampling lines and hoses should be adequately flushed prior to taking a sample. Samples should be stored in a cool, dark place. Procedures shall be in accordance with ASTM D4057, D4177 or D5854.
 
'''7.1.1'''     Sampling equipment and procedures shall be designed and used to obtain representative samples of a product. Sampling lines and hoses should be adequately flushed prior to taking a sample. Samples should be stored in a cool, dark place. Procedures shall be in accordance with ASTM D4057, D4177 or D5854.