Changes

Jump to navigation Jump to search
no edit summary
Line 101: Line 101:  
| '''6.3''' || Flash point, °C (see 6.19) || Min. || 40.0 || 40.0 || 40.0 || 54.0 || 54.0 || 60.0 || D93<sup>[[CGSB_ONGC/003_0002_2019_ENG#Normative_a|a]] </sup>, D3828, D7049  
 
| '''6.3''' || Flash point, °C (see 6.19) || Min. || 40.0 || 40.0 || 40.0 || 54.0 || 54.0 || 60.0 || D93<sup>[[CGSB_ONGC/003_0002_2019_ENG#Normative_a|a]] </sup>, D3828, D7049  
 
|-
 
|-
| '''6.4''' || Kinematic viscosity, at 40°C, mm<sup>2</sup>/s (cSt)(see 6.25) || Min. || 1.20 || 1.30 || 1.70 || 5.5 || ― || ― ||D445, D7042 or D7945  
+
| '''6.4''' || Kinematic viscosity, at 40°C, mm<sup>2</sup>/s (cSt)(see 6.25) || Min. || 1.20 || 1.30 || 1.70 || 5.5 || ― || ― ||D445 a<ref>The referee method to be used in the event of a dispute</ref> , D7042 or D7945  
 
|-
 
|-
 
|  || || Max. || 2.00 || 2.50 || 3.60 || 24.0 || ― || ―
 
|  || || Max. || 2.00 || 2.50 || 3.60 || 24.0 || ― || ―
Line 125: Line 125:  
| Example || Example || Example || Example || Example || Example || Example || Example || Example
 
| Example || Example || Example || Example || Example || Example || Example || Example || Example
 
|}
 
|}
 
+
<references> Normative References in Specified Values </references>
<h4> Normative References in Specified Values </h4>
+
   
*Normative_a The referee method to be used in the event of a dispute.
       

Navigation menu

GCwiki